Quote Now


Solutions for Your Industry, Ready for Your Choice

%{tishi_zhanwei}%

Contact Us

E-mail:

vincent@kadvinint.com

WhatsApp/Phone:

8618331290902

Address:
No. 158, Bao Feng North Street, Wutai Township, Lianchi District, Baoding City, Hebei Province, China

+
Refcomp three parallel screw unit
  • Refcomp three parallel screw unit
Refcomp three parallel screw unit
+
  • Refcomp three parallel screw unit

Refcomp three parallel screw unit


1.Parallel unit component : Stand metal chassis;Lifting ring;Vibration-damping pad.2.Reservoir assembly:Reservoir, equipped with 28bar safety valve;Reservoir inlet and outlet shut-off valve;Reservoir with sight glass;Pipeline sight glass;Reservoir outlet filter drier barrel, contains filter element;Filter drier barrel outlet is equipped with shut-off valve.

WhatsApp:

Product Description Download
  • Product Description
  • 1.Parallel unit component

    • Stand metal chassis
    • Lifting ring
    • Vibration-damping pad

    2.Reservoir assembly

    • Reservoir, equipped with 28bar safety valve
    • Reservoir inlet and outlet shut-off valve
    • Reservoir with sight glass
    • Pipeline sight glass
    • Reservoir outlet filter drier barrel, contains filter element
    • Filter drier barrel outlet is equipped with shut-off valve

    3.Exhaust gas assembly

    • External oil separator (with oil sight glass)
    • Oil separator exhaust outlet check shut-off valve
    • Oil separator outlet shut-off valve
    • Oil heater
    • Oil temperature controller
    • Oil level controller

    4.oil line assembly

    • Oil line outlet filter barrel, contains filter element
    • Oil line ball valve
    • Oil line solenoid valve
    • Oil line sight glass
    • Electronic oil flow switch

    5.Single compressor assembly

    • Suction and discharge shut-off valve
    • Discharge check valve
    • Compressor vibration-damping pad
    • Suction filter barrel, contains filter element
    • First stage liquid spray cooling system
    • Oil sight glass

    6.Economizer assembly(applies when evaporatingtemperature < -20°C)

    • Economizer
    • ECO expansion valve, ECO solenoid valve,ECO liquid sight glass,ECO shut-off valve

    7.Gas-liquid separator

    8.Compressor unit electric control &protection assembly

    • Compressor high-low pressure controller
    • Compressor oil flow controller
    • Electronic overcurrent protection
    • Low pressure sensor
    • Independent circuit breakers and thermal protectors
    • PLC controller with color touch screen

    9.Fluid supply manifold and returnmanifold assembly

    • Fluid supply manifold and return manifoldquantity in accordance with product catalog
    • Manifold adopts hard straight pipe

    10.Other

    • Compressor pressure gauge
    • Repair valves are mounted on each manifold
    • Insulation materials for suction,economizer and cooling tube
    • Compressor unit suction shut-offvalve

    11.Optional configurations

    • Refrigerant R22 or R404A
    • Reservoir can be vertical or horizontal
    • Fluid supply manifold shunt and return manifold shunt
    • Coolingtype: air cooled,water cooled, evaporative cooled
    • Oil cooling type: air cooled, water cooled, thermosiphon cooled
    • Other brand compressors and configurations

    12.Components that can be added

    • Compressorexhaust muffler
    • High pressure sensor
    • Condensing pressure regulating valve
    • Heat recovery device
    • Hot gas defrost function
    • Frozen oil
About Us

Hebei Kadvin Refrigeration Technology Group Co., Ltd. is a modern comprehensive refrigeration enterprise integrating R&D, production, and sales of refrigeration equipment. We offer a one-stop supply of full-category refrigeration equipment and supporting accessories, and professionally undertake various large and medium-sized cold storage projects.

Workshop equipment
Processing workshop
Processing equipment
Our Advantages

Factory Direct Supply

OEM & ODM

High Quality

Easy to Operate

Timely delivery

One-stop Service

Exhibition

Our products are exported to more than 20 countries and regions worldwide. We support in-depth customized production to adapt to voltage standards and climatic operating conditions of different regions. Together with overseas partners, we build a stable and efficient global cold chain supply network.

Attend a trade show 08
Attend a trade show 07
Attend a trade show 06
Attend a trade show 05
Attend a trade show 04
Attend a trade show 03
Attend a trade show 02
Attend a trade show 01
Payment and Distribution

T/T L/C

★ If your order is not large, we can send it to you via TNT, DHL, UPS or EMS, etc.

★ If your order is large, we would recommend that you use air or sea freight through the freight forwarder you specify. We also have long-term cooperative agents.

TNT

7 to 10 working days

EMS

7 to 10 working days

DHL

7 to 10 working days

ups

7 to 10 working days

FedEx

7 to 10 working days

FAQ

How often should cooling equipment be maintained? What kind of maintenance does it need?

For regular industrial units, it's recommended to do maintenance every 3 to 6 months; clean the dust from the condenser and evaporator; wash the filters; check the electrical wiring and compressor running current; check the refrigerant pressure and all seals; tighten the pipe brackets.

Can you add refrigerant to the cooling system however you want?

No. You need to check for leaks first, and after fixing any leaks, fill according to the model number on the equipment nameplate. You can't mix refrigerant types, and adding too much or too little can damage the compressor.

The machine is running fine, but it's cooling slowly and there's not enough cold.

① The condenser is clogged with dust, so the heat dissipation is poor; ② The evaporator has frost or scale buildup, reducing heat exchange efficiency; ③ Refrigerant leaks or not enough refrigerant; ④ The circulating water flow is too low; ⑤ The ambient temperature is beyond the equipment's rated range; ⑥ Damage to the insulation layer causes loss of cooling.

Is the refrigeration unit starting and stopping frequently, constantly turning on and off?

① The temperature sensor is displaced or damaged, causing inaccurate temperature readings; ② Poor heat dissipation, making the high-voltage protection trip frequently; ③ The system has too much or too little refrigerant; ④ Voltage instability triggers compressor overload protection; ⑤ Insufficient flow from the circulating water pump triggers water flow protection.

What's the reason the device won't start after being powered on?

First, check if the power voltage, circuit breaker, and wiring are normal; check the thermostat setting, because if the set temperature is higher than the ambient temperature, the unit won't start; also check if the high and low voltage protection, water flow protection, and overload protection have been triggered; faults in the contactor or thermal relay can also prevent the unit from turning on.

Product Manual

Product Manual

File size:

30.5MB

Update time:

Jul 30,2026

Inquire Now

Note: Please leave your email address, our professionals will contact you as soon as possible!

Variable frequency hot gas defrost cold storage unit

The installation method is simple,without the need to weld throttle valves. The electric control box is integrated, and wiring is straight-forward. Simply supply power to the external unit and it is ready to use.

Fully enclosed all-in-one machine

The company mainly develops, produces, and sells H-type, V-type, L-type, and U-type air-cooled condensers; cooling fans, standard fans, water-defrost fans; unit-type systems, variable-frequency heat-fluorine defrost units for refrigeration and cold storage; semi-hermetic piston units; single screw units and parallel units; cold storage hook plates; energy-saving aluminum fins, quick-freezing shelves, and other refrigeration accessories in a one-stop supply, handling all kinds of large-scale cold storage projects.

Semi-enclosed piston unit

According to the needs of market development, the company launched semi-hermetic air-cooled con-densing units and semi-hermetic box-type condensing units, to meet the different needs of 12℃~40℃,widely suitable for medical machinery, food, biopharmaceutical, chemical industry and other indus-tries.

Variable frequency hot fluorination frost unit

The installation method is simple,without the need to weld throttle valves. The electric control box is integrated, and wiring is straight-forward. Simply supply power to the external unit and it is ready to use.
< 123 >